- id_13106541
- Version: 4.7
- Date: Feb 27, 2020 11:17:37 AM
Penetration Cabinet
PEN Cabinet
| Item | Part Number | Description | |
| 1 | 5199042 | Top Input/Output Panel | |
| 2 | 5167035 | Fiber Optic CAN Assembly | |
| 5167035-51 note: Must be used with compatible SW loads DV25.1 R02 or earlier.
|
Fiber Optic CAN Assembly (RoHS) | ||
| 5167035-52 note: Compatible with SW loads DV25.1 R03 and later.
|
|||
| 3 | 2352972 | Shim Supply Module | |
| 5459459 | Shim Supply Module (RoHS) | ||
| 4 | 5160446-2 | Driver Module FRU | |
| 5446983 | Driver Module FRU (RoHS) | ||
| 5 | 5167111 | Patient Handling Power Supply 2 (includes the following items) | |
| 5167111-51 | Patient Handling Power Supply 2 (RoHS) Please order 5167111-51 for DV25.1 or earlier even though it can technically be for later versions. (includes the following items) | ||
| 5167111-52 | Patient Handling Power Supply 2 (RoHS) (not compatible with DV25.1 SW or earlier) (includes the following items) | ||
| 5317366 | J35 37-Pin Sub-D Filter | ||
| 5311961 | J36 25-Pin Sub-D Filter | ||
| 5317368 | J54 9-Pin Sub-D Filter | ||
| 6 | 5251938 | SRPS Control Board Assembly | |
| 5251938-2 | SRPS Control Board Assembly | ||
| 7 | 5231801-3 | Scan Room Power Supply, 16- and 32-Channel | |
| 8 | 5263700 | Fan Assembly | |
| 9 | 5166815-2 | Power Distribution Unit | |
| 5166815-3 | Power Distribution Unit for eSRPS | ||
| 10 | 5402528 note: Must be used with compatible SW loads DV25.1 R02 or earlier.
|
EcoPower Scan Room Power Supply (eSRPS) | |
| 5402528-51 note: Compatible with SW loads DV25.1 R03 and later.
|
|||
| 11 | 5154662 | Reference Clock and NB Exciter Module (1.5T) | |
| 5480028 | Reference Clock and NB Exciter Module (1.5T, RoHS) | ||
| - | - | ||
| - | - | ||
| 5764096 | SFP Fiber Optic Transceiver Module | ||
| 5764096-2 | SFP Fiber Optic Transceiver Module | ||
| 12 | n/a | Item does not apply to this system | |
| 13 | n/a | Item does not apply to this system | |
PEN Cabinet Penetration Panel
| Item | Part Number | Description | |
| 1 | 5213397 | Dual Blower Box (for Patient and RF Hub) | |
| 5213397-100 | Dual Blower Box (for Patient and RF Hub) (RoHS) | ||
| 2 | 5265337 | Air Inlet Filter | |
| 3 | 5173240 | High Order Shim (HOS) Filter Assembly (includes HOS Cable Kit) | |
| 5495165 | High Order Shim (HOS) Filter Assembly (includes HOS Cable Kit) (RoHS) | ||
| 5263312 | High Order Shim (HOS) Cable Kit (includes the following cables, which are located on the other side of the penetration panel) | ||
| 5165780* | CAN Cable | ||
| 2351607-3* | Power Cable, C14 to C13, 2m | ||
| 5203240* | High Order Shim (HOS) Supply to Filter Cable | ||
| 4 | 2323698 | 1 kV Dynamic Disable Filter Module | |
| 5 | 5199431 | SRPS Access Panel PEN Cabinet | |
| 6 | 5402850 | eSRPS Filter Box | |
| 7 | 5310321 | Ferrite Clamp | |
| 8 | 5402530 | Access Panel for eSRPS | |
| *Item not sold as an individual FRU | |||
PEN Internal Cable FRU Kits
| 2322434 | 5168641 | 5168043 | 5168317 | 5167882 | 5166461 |
| 5165866 | 5166997 | 5169443 | 5172726 | 5166354-2 | 5171626 |
| 5170521 | 5172868 | 5167365 | 5171583 | 5172959 | 5169381 |
| 5168461 | 5168597 | 5172812 | 5172595-2 | 5169345 | 5175777 |
| 5172595 |
| 5419641 | 5575011 | 5575010 |
| 5181464 | 5166512-3 | 5172955 | 5172955-2 | 5166749 | 5166749-9 |
| 5172679 | 5172679-10 | 5172679-11 | 5419638 | 5419638-2 |
| 5165866 | 5166997 | 5419641 | 5168043 | 5168317 | 5169443 |
| 5172679 | 5172726 | 5166749 | 5166749-9 | 5172679-10 | 5172679-11 |
| 5575011 | 5575010 |
| 5167143 | 5167143-2 | 5172838 | 5155030 | 5172849 | 5171737 |
| 5154994 |
| 5181464 | 5166512-3 | 5166512-2 | 5172955-2 | 5172955 | 5166749 |
| 5166749-9 | 5172679-10 | 5172679-11 | 5172679 |
| 5165866 | 5166997 | 5169443 | 5172726 | 5166354-2 | 5171626 |
| 5170521 | 5172868 | 5167365 | 5171583 | 5172959 | 5169381 |
| 5168461 | 5168597 | 5172812 | 5172595-2 | 5169345 | 5175777 |
| 5172595 |