System Cable FRU
| Part Number | Description |
| 5477605-2 | Run P2003 ISC-ICE-J1, 2, 5 to MAG-DPP1 J6, 9, DPP2 J6, 17050 mm |
| 5477605-4 | Run P2004 ISC-ICE-J6, 13, 14 to MAG-DPP2 J9, DPP3 J6, 9, 17700 mm |
| 5477605-8 | Run P2006 ISC-ICE-J30 to MAG-RXDIST J16, Spares, 17800 mm |
| 5476645-2 | Run P2009 MAG-PAC J1 to ISC-ICE-J38, J39, CAN Fiberoptic, 16550 mm |
| 5476646-2 | Run P2010 MAG-SRI J11_J12 to ISC-ICE-J40_J41, CAN Fiberoptic, 17400 mm |
| 5476646-3 | Run P2011 MAG-SRI J13 J14 to ISC-PHPS2-J37_J38, CAN Fiberoptic, 17150 mm |
| 5475817-2 | Run M3311 ISC-PHPS2-J36 to Table IO-J5, D-sub, Long Drive Power, Nonmagnetic, 18500 mm |
| 5476366-2 | Run M3315 ISC-PHPS2-J54 to Table IO-Table Cont Box-J4, Halls Signal, Nonmagnetic, 18500 mm |
| 5476816 | Run M3314, Cable IRD_OCP power, Nonmagnetic |
| 5475829-2 | Run M3313 ISC-PHPS2-J35 to Table IO-Table Cont Box-J8, TABLE POWER, Non Magnetic, 18500 mm |
| 5476352-3 | Run M1302, ISC-PW-J29 to RxDist-J19, Receiver Clock, Twinax, 15,140 mm |
| 5476352-4 | Run M1304, ISC-PW-J30 to MAG-RxDist-J10, Rx LO, Twinax, 16,330 mm |
| 5476371-2 | Run M3316 ISC-PW-J17 to MAG-Rx Dist-J18, Inhibit, Nonmagnetic, 15140 mm |
| 5476630-2 | Run M1303, MAG-RxDist-J12 to ISC-PW-J32, Loopback, 15,550 mm |
| 5476767-2 | Run M3384 ISC-PW-J75 TO MAG-DTRSW J7, 15000 mm |
| 5476767-44 | Run M3385 ISC-PW-J76 TO MAG-DTRSW J8, 15000 mm |
| 5476636-2 | Run M3300 ISC-PW-J112 to MAG-Rx Dist J1, Rx Dist Power, 24W7, Low-Mag, 15750mm |
| 5476751-2 | Run M3302 MAG-SRI-J1 to ISC-PHPS2-J40,SRI Power,Nonmagnetic, 15000 mm |
| 5475840-2 | Run M3303 ISC-PHPS2-J39 to MAG-SRI J21, MCPDB Interface, Nonmagnetic, 15000 mm |
| 5475830 | Run M3360 ISC-PHPS2-J41 to MAG-PAC-J2, MAG-PAC-J9 Y-Cable DV PAC for Power and One-Wire,15000 mm |
| 5476796 | Run M1315, MAG-RxDist-J11 to MAG-Extended Bridge Rear Support TNS Antenna, Phase-Length Controlled |
| 5476790 | Run M1335 MAG-AMP-J11 to MAG-RX Dist-J13, Cable, Body Receive, 5000 mm |
| 5475852 | Run M1352 MAG-BORE-J2 to MAG-DTRSW-J2, 3.0T Dual Body CH1, 3406 mm ref |
| 5475852-2 | Run M1353 MAG-BORE-J3 to MAG-DTRSW-J3, 3.0T Dual Body CH2, 3406 mm ref |
| 5498246-5 | Run M1354 MAG-DTRSW-J5 to MAG-AMP-J9, Body Receive, 710 mm |
| 5498246-6 | Run M1355 MAG-DTRSW-J6 to MAG-AMP-J10, Body Receive, 710 mm |
| 5475880 | Run M1357 MAG-DPP1 J1 to MAG-Table IO-J17, DPP1 RF Signal 2130 mm |
| 5475880-2 | Run M1358 MAG-DPP1 J2 to MAG-Table IO-J18, RF Signal, 2130 mm |
| 5475880-3 | Run M1360 MAG-DPP2 J1 to MAG-Table IO-J20, RF Signal, 2570 mm |
| 5475881-2 | Run M1359 MAG-DPP2-J3 to MAG-Table IO-J19, Pport BNC CONN 4, Coil Status, 2570 mm |
| 5475880-4 | Run M1361 MAG-DPP2-J2 to MAG-Table IO-J21, RF Signal, 2570 mm |
| 5475881-3 | Run M1362 MAG-DPP2-J4 to MAG-Table IO-J22, Pport BNC CONN 1Coil Status, 2570 mm |
| 5475881-4 | Run M1363 MAG-DPP3-J3 to MAG-Table IO-J23, Pport BNC CONN 3, Coil Status, 3310 mm |
| 5475880-5 | Run M1364 MAG-DPP3 J1 to MAG-Table IO-J24, RF Signal, 3310 mm |
| 5475881 | Run M1356 MAG-DPP1-J3 to MAG-Table IO-J16, Pport BNC CONN 2, Coil Status, 2130 mm |
| 5475880-6 | Run M1365 MAG-DPP3-J2 to MAG-Table IO-J25, RF Signal, 3310 mm |
| 5481324-2 | Run M1366 CABLE, Rx LO, DPP1-J10 to RxDistr-J7 |
| 5481324-3 | Run M1367 CABLE, Rx LO, DPP2-J10 to RxDistr-J6 |
| 5481324-4 | Run M1368 CABLE, Rx LO, DPP3-J10 to RxDistr-J5 |
| 5475870 | Run M3337 MAG-SRI-J4 to MAG-LCP-J1, 4500 mm and MAG RCP J1, 1500 mm, Nonmagnetic (Compatible with 5475870-2) |
| 5475870-2 | Run M3337, MAG-SRI-J4 to MAG-RCP-J1, 5,100 mm and MAG-LCP-J1, 2,150 mm |
| 5495564 | Run M3341 MAG-SRI-J20 to Table IO-J1,LANDMARK, D-sub Nonmagnetic, 3180 mm |
| 5476792 | Run M3342, MAG-SRI-J23 to Bore Patient Alignment Light |
| 5788763 | Run M3344 MAG-SRI-J22, Bore Lights and Heat Exchanger Temp, Nonmagnetic (600 mm) |
| 5549343 | Run M3393, Rear Bore Light A (3200 mm and 2500 mm) |
| 5549343-2 | Run M3394 Front Bore Light A (3200 mm and 2500 mm) |
| 5475873-2 | Run M3345, MAG-SRI-J31 to MAG-Table IO-J3, Table Front Microphone, 3,970 mm |
| 5476356 | Run M3346, MAG-SRI-J32 to Table IO-J4, Rear Microphone, 3,950 mm |
| 5183628 | Run M3347 MAG RJ10 to MAG-Rear Endbell Speaker |
| 5476794 | Run M3348, MAG-SRI-J34 to RJ10, Comfort Module Speaker Cable, 4,600 mm |
| 5475876 | Run M3351, TCB-J5 to MAG-SRI-J2, Table Feedback, 3,400 mm |
| 5476777-4 | Run M3367, MAG-DPP1-J7 to MAG-RxDist-J4, 44-Pin Sub-D, 1,150 mm |
| 5476777-5 | Run M3368, MAG-DPP2-J7 to MAG-RxDist-J3, 44-Pin, Sub-D, 725 mm |
| 5476777-6 | Run M3369, MAG-DPP3-J7 to MAG-RxDist-J2, 44-Pin, Sub-D, 350 mm |
| 5475869 | Run M3370, MAG-SRI-J3 to TCB-J6 Dock Control, 3,450 mm |
| 5475860 | Run M3380 MAG-Rx Dist-J58 to DTRSW J20, MAG-Bore-J9, MAG-PREAMP-J9, Hart ID Cable, Nonmagnetic |
| 5476775 | Run M3382 MAG-J61 to Parenthesis Light Left, 1000 mm |
| 5476775-2 | Run M3383, MAG-J62 to Right Parenthesis Light, 4,000 mm |
| 5476775-3 | Run M3506 MAG-Front-Upper Cover J63, 4000 mm |
| 5495209-3 | Run M3386 Table IO-J6 to MAG-PAC-J5 J6, Peripheral Gating Cable for MR Kizuna, 3000 mm |
| 5570806-2 See Note. | ECG Patient Lead Wire
Note:
5570806 is discontinued. Please order per following instruction.
|
| 5476367-2 | ECG Cable Extension, mm |
| 5495369 | Run M3504, MAG-RxDist-J57 to TCB-J9 RxDist Power, 3,270 mm |
| 5476753-4 | Run M4005 ISC GND STUD to MAG-GND STUD, 17500 mm |
| 5476353 | Run M3339, ICC PW-J118 to MAG-SRI-J33, Console Intercom, 15,600 mm |
| 5475898 | Run M3391 ISC-PW-J48 to MAG-Rx Dist J14, DPP ICE Diag,Nonmagnetic, 18500 mm |
| 5476351 | Run M3030 ICC PI J18 to E-OFF, 30000 mm |
| 5492344 | Run M3505 Extended Bridge-EOT to TCB-J10, D-Sub, EOT Switch, 5,900 mm |
| 5561243 | Run M3507 Extended Bridge-EOT Connect to Run M3505, EOT Switch, 200 mm |
| 5476357 | Run E3011 ISC-IO-J2 to OW-PortB, Ethernet, 30000 mm |
| 5476626 | Run E3018 OW-PDM-J3 to ISC-IO-J12, HART-RS422, 30000 mm |
| 5756510 | USB Extender Cable FRU Kit, Improved Signal Quality (Including the following parts)
|
| 5479529 | Run E3501 ISC-IO-J26 to Run E3047, 30000 mm |
| 5502144 | RUN E3042 ISC-IO-J112 to OW-PDM-J2, 30,000 mm |
| 5476361-2 | Run E3014 ISC-PI-IO J20 to RF Door SW, E-Stop, 25000 mm |
| 5476359 | Run E0003, OW-PDM-J1 to ISC IO-J102, Host Power, 30,000 mm |
| 5476361 | Run E3030 ICC-IO-J115 to E-Off SW, E-off,17000 mm |
| 5538322 | GOC-PWM-J2 TO IEEE1394 and TO E3042 |
| 5476815 | Run M1350 ISC-PW-J106 to MAG-DTRSW-J1, 3.0T Dual Body Tx,14463 mm ref |
| 5476815-2 | Run M1351 ISC-PW-J109 TO MAG-DTRSW J4, 3.0T Dual Body Tx,14463 mm ref |
| 5476647-4 | Run M3317 Gradient Cable X, Scan Room, Long, 12700 mm |
| 5476647-5 | Run M3318 Gradient Cable Y, Scan Room, Long, 12700 mm |
| 5476647-6 | Run M3319 Gradient Cable Z, Scan Room, Long,12700 mm |
| 5475877 | Run M1305 ISC- J122 TO Mag-Table IO J15, RF Transmit, 18379 mm |
| 5476815-3 | Run M1350 ISC-PW-J106 TO MAG-DTRSW-J1, 3.0T Dual Body Tx, 10380 mm ref |
| 5476815-4 | Run M1351 ISC-PW-J109 TO MAG-DTRSW J4, 3.0T Dual Body Tx, 10380 mm ref |
| 5476647 | Run M3317 Gradient Cable X, Scan Room, Short, 8700 mm |
| 5476647-2 | Run M3318 Gradient Cable Y, Scan Room, Short, 8700 mm |
| 5476647-3 | Run M3319 Gradient Cable Z, Scan Room, Short, 8700 mm |
| 5475877-2 | Run M1305 ISC- J122 TO Mag-Table IO J15, RF Transmit, 14295 mm |
| 6859057-2 | RUN E3040 ICC- J2 to ISC-J108, 4,500 mm |
| 5475834-2 | RUN E0010 ICC_J5_ISC_J44, 5000 mm |
| 5476823-2 | Run E0007 ISC-T2 to ICC-J1, 4000 mm |
| 6859057 | RUN E3040 ICC- J2 to ISC-J108, 10,000 mm |
| 5475834 | Run E0010, ICC-J5 to ISC-J44, 10,000 mm |
| 5476823 | Run E0007 ISC-T2 to ICC-J1, 10000 mm |
| 5481324 | Cable_TX481, Ref Clock, CLKS1-J3 to ICE PSC-J28 |
| 5481308 | Cable, DVMRLINK, ICE-J29T to Exciter-J19 |
| 5481308-2 | Cable, DVMRLINK, PSC-J31T to GP4-J1 |
| 5486811 | Cable, AC TRIGGER, ICE TO Cabinet Monitor, J43 |
| 5481312-2 | Cable_TX503, BD4, Driver Module-J25 ISC-PW-J96 Filter |
| 5481312 | Cable_TX502, BD1, Driver Module-J21 ISC-PW-J95 Filter |
| 5180907-53 | Run M3350 MAG-SRI-J10 to MAG-BORE, Bore Temperature, RoHS |
| Equipment Room Part# | Description |
|---|---|
| 5858947 | Run E3324 PW-J5 to ISC-IO-J143, DCPS for IRD |
| 5858948 | Run E3314, PW-J42 to ISC-IO-J42, Display Power |
| 5858952 | Run E3311 ISC-IO-J36 to PW-J36, D-sub, Long Drive Power |
| 5477605-15 | Run P2004 ISC-ICE-J6, 13, 14 to MAG-DPP2 J9, DPP3 J6, 9, 34.7m |
| 5476646-6 | Run P2011 MAG-SRI J13 J14 to ISC-PHPS2-J37_J38, CAN Fiber Optic, 34.15m |
| 5476646-7 | Run P2010 MAG-SRI J11_J12 to ISC-ICE-J40_J41, CAN Fiber Optic, 34.4m |
| 5861075 | Remote Siting (Off the Wall) Cable Run E3300 ISC-IO-J112 to PW-J2, Rx Dist Power, 24W7, Low-Mag |
| 5858971 | Run E1302 ISC-PW-J29 TO ISC-IO-J29, Receiver Clock, Twinax, 17.50m |
| 5860964 | Remote Siting (Off the Wall) Cable Run E4005 ISC-GND to PP-GND |
| 5881836 | Remote Siting (Off the Wall) Gradient Cable FRU, 17m, Equipment Room Side |
| 5881837 | Remote Siting (Off the Wall) Gradient Cable FRU, 13.5m, Scan Room Side |
| 5747058 | Run E1051, ISC-J109 to PEN-J109, 3.0T Body, 10,327 mm |
| 5747059 | Run E1001, ISC-J106 to PEN-J106, 3.0T Body, 10,327 mm |
| 5747768 | Run E1002, ISC-J122 to PEN-J122, RF Transmit, 10,218 mm |
| 5747058-3 | Run M1351, DTRSW-J4 to PEN-J109, 3.0T Body, 10,500 mm |
| 5747059-3 | Run M1350, DTRSW-J1 to PEN-J106, 3.0T Body, 10,500 mm |
| 5747761 | Run M1305, PEN-J122 to Mag-HDTX-IO-J2, P2 RF Transmit, 14,305 mm |
| 5747768-2 | Run E1002, ISC-J122 to PEN-J122, RF Transmit, 16,348 mm |
| 5747058-2 | Run E1051, ISC-J109 to PEN-J109, 3.0T Body, 16,523 mm |
| 5747059-2 | Run E1001, ISC-J106 to PEN-J106, 3.0T Body, 16,523 mm |
| 5747058-4 | Run M1351, DTRSW-J4 to PEN-J109, 3.0T Body, 14,631 mm |
| 5747059-4 | Run M1350, DTRSW-J1 to PEN-J106, 3.0T Body, 14,631 mm |
| 5747761-2 | Run M1305, PEN-J122 to MAG-HDTX-IO-J2, P2 RF Transmit, 18,392 mm |
| Part Number | Description |
|---|---|
| 5778287-8 | USB-AOC optic fiber cable, Host PC USB3.0 port to IRD-Right-J3, Run# P2027 48000mm, GEN2 |
| 5778287-9 | USB-AOC optic fiber cable, Host PC USB3.0 port to IRD-Left-J3, Run# P2029 48000mm, GEN2 |
| 5879076 | DP AOC, GOC DP Dongle to IRD Right DP, Run P2026 48000mm |
| 5879076-2 | DP AOC, GOC DP Dongle to IRD Left DP, Run P2028 48000mm |
| 5851077-2 | Mini DP to DP Dongle for port 1 |
| 5851077-3 | Mini DP to DP Dongle for port 2 |