Option key catalog matrix

Refer to the table below for a list of available electronic options for MR scanners.

Note: The options list below may change periodically. To see the most current keys, refer to the official drawing prints for each part.
Table 1. New option keys from DV26
Short name Option key long name MCAT number Part number Protocol information
hypersenseHypersenseM7006AF5748554Hyper Sense
cine3d3D CineM7006AM 57485573D CINE
flow4d4D FlowM7006BB or M7006AB or M7006BC or M7006AD57485584D FLOW
cardt1mapCardiac T1 MappingM7006AC5748559T1 MAP
cardt2mapCardiac T2 MappingM7006AC5748561T2 MAP with Cardiac Gating
hyperbandHyperbandM7006AA5748139Hyper Band
syndwiSynthetic DWIM7006AE5748563Synethic DWI
flexFlexM7006AW5748565FSE Flex & Cube Flex
exsiExternal Scanner InterfaceM7006AZ5748566N/A - just enables FUS EXSI
brnwavrsBrainwave Resting StateM7006AJ5748501Brainwave Resting State
brnwavpxeBrainwave Host PXEM7006AL5748503 and 5749267
brnwavssBrainwave Skull StripM7006AT5748215
brnwavtgBrainwave Tract GenerationM7006BA5748365
secureadvSIGNA Secure AdvancedM7006AH5748922SIGNA Secure Advanced (High Security Option)
hypercubeHyperCubeM7006AG5748924Hyper Cube (Cube Focus)
READY_VIEW_MRTOUCHMRTOUCHM7000MT5365931MR Touch
Volume_ViewerVolume ViewerPart of SignaWorksN/A
Integrated_RegistrationIntegrated RegistrationPart of SignaWorksN/A
READY_VIEWReady ViewPart of SignaWorksN/A
READY_VIEW_BODY_VIEWReady View Body ViewPart of SignaWorksN/A
READY_VIEW_Brain_ViewReady View Brain ViewPart of SignaWorksN/A
VV_APIVolume Viewer APIPart of SignaWorksN/A
Table 2. New option keys from DV25.1
Short name Option key long name MCAT number Part number Protocol information
magicMAGiCM7005DJ5717235MAGiC application & post processing
Table 3. New option keys from DV25
MCAT number Option key shot name Short name Customer protocol
M7005DAMDE PlusmdeplusMDE enhancements
M7005DBDISCOdiscoView-shared time resolved 3D imaging
M7005DCSilent Propeller silentprpSilent Propeller Body imaging
M7005DDMR750 Dual Drive dualdriveDual Drive on MR750
M7005DGDW PrepdwprepDiffusion Preparation
Table 4. Option Key Catalog Matrix for Model Type “MR”
Option catalog Options activated Customer protocol
G3335DF DELENHMTdelenhmtDelayed Enhancement
G3335DG FIESTA2Dfiesta2d2D Fiesta
G3335DH FIESTA3Dfiesta3d3D Fiesta
G3335DJ FTMRAftmraFluoro Triggered MRA
G3335DK HISRIShisrisModality WorkList
G3335DL MNSmnsMulti-Nuclear Spect
G3335DM NAVIGATORnavigatorNavigator
G3335DN PERFUSIONperfusionPerfusion
G3335DP PPSppsPPS
G3335DR PROBE3Dprobe3d3D Probe
G3335DS PROBE99probe99Probe 2000 Upgrade
G3335DT PROBEPprobepProbePRESS
G3335DW PROSEproseProbe 3D Prostate
G3335DY RTCArtcaiDrive Pro Plus
G3335DZ RTETrtetReal-Time FGRE-ET
G3335E SAGEsageSpectro Analysis GE
G3335EA SPECTROspectroSpectroscopy/PROBE
G3335EB SPIRALHRspiralHRSpiral Hi-Res
G3335EC SPIRALRTspiralRTSpiral Real-Time
G3335ED TAGGINGtaggingCardiac Tagging
G3335EE TENSORtensorDiffusion Tensor
Table 5. Option Key Catalog Matrix for Model Type “MR” (continued)
Option catalog Options activated Customer protocol
M1033BL FMRI BASE HARDWARE brnwavhwBrainwave Light Hardware
M1033BS BRAINWAVE POST ACQUISITION brnwavpaBrainwave PA
M1033BT BRAINWAVE REAL TIME ACQ brnwavrtBrainwave RT
Table 6. Option Key Catalog Matrix for Model Type “MR” (continued)
Option catalog Options activated Customer protocol
M3033NB 3.0T SCANTOOLS 12.0 acgdplus ACGD Plus
bloodsupp Blood Suppression
cine Cine
e3dtof 3D Time of Flight
epli Echo Planer Imaging
fastcine Fast Cine
fastgrass Fast Gradient Echo
flairepi Flair EPI
FR3DFSE 3D FSE
fse2 Fast Spin Echo & Flair
fsexl FSE-XL
gtof Time of Flight
idrive iDrive
idrivePro iDrive Pro
pcvi Phase Contrast Vascular Imaging
sgd SGD_EchoSpeed
sgdperf SGDPerf
smartprep Smart Prep
special SPECIAL
sprep99 Smart Prep 2000 upgrade
ssfse SSFSE
ssfsemrcp SSFSE MRCP/Body Pak
ssfsexl MRCP3
t1bhold T1 Breath Hold
t2bhold T2 Breath Hold
threeplane Three Plane Localizer
ushorttrUltra Short TR
M3033NC LAVA OPTION KEY lavaLava
M3033NG HD MR ECHO realcardRealCARD
M3033NH HD PROPELLER propt2 Propeller
propdwiPropeller
M3033NJ PROSE FOR EXCITE proseProbe 3D Prostate
M3033NK TRACTOGRAPHY tractoTractography (FiberTrak)
M3033NL 1.5T 2D FATSAT FIESTA fiesta2dfs 2D FatSat Fiesta
fiesta2d2D Fiesta
M3033NR 3D FLAIR FLAIR3D3D FLAIR
M3033PJ PERFORMED PROC STEP EXCITE ppsPPS
M3090BD ACGD SR77 OPTION KEY hispeedHigh Speed
M3090BE ACGD SR120 OPTION KEY sgdSGD_EchoSpeed
M3090KJ 2D FIESTA fiesta2d2D Fiesta
M3090KK 3D FIESTA fiesta3d3D Fiesta
M3090KR 2D DELAYED ENHANCEMENT EX delenhmtDelayed Enhancement
M3090LA EXCITE II MNS KIT

M3090LB EX II FWD PRD MNS KIT

M3090LC EXCITE II LEGACY MNS UPGRADE

mns Multi-Nuclear Spect
spectro Spectroscopy/PROBE
probe99 Probe 2000 Upgrade
sageSpectro Analysis GE
M3090LF HISPEED PLUS KEY EXCITEII hispeedHigh Speed
M3090LG ECHOSPD PLUS KEY EXCITEII sgdSGD_EchoSpeed
M3090LP ECHO PLUS dwepiDiffusion Weighted epi
M3090LR DIFFUSION TENSOR EXCITE tensorDiffusion Tensor
M3090MA PROBE 2000 probe99 Probe 2000 Upgrade
probepProbePRESS
M3090MB PROBE 2000 UPG FOR EXCITE probe99Probe 2000 Upgrade
M3090MC SAGE 7 FOR EXCITE sageSpectro Analysis GE
M3090MD PROBER 3D BRAIN FOR EXCITE probe3d3D Probe
M3090ME PROBE-S spectroSpectroscopy/PROBE
M3090PL CONNECTPRO hisrisModality WorkList
M3100LA 1.5T MNS BASE KIT

M3100LD 1.5T MNS UPGRADE KIT

M3100LG 1.5T MNS BASE KIT 4KW AMP

mns Multi-Nuclear Spect
spectro Spectroscopy/PROBE
probe99 Probe 2000 Upgrade
sage Spectro Analysis GE
probep ProbePRESS
probe3d Probe 3D
spectroSpectroscopy/PROBE
M3100LE 3-II WITH MNS TO E-III MNS UPGRADE probep ProbePRESS
probe3d Probe 3D
spectro Spectroscopy/PROBE
probe99Probe 2000 Upgrade
M3200AA HDI 1.5T 8 CH 2 BLADE

M3200AD CRM-SALT PREEX to HDI 8CH UG

M3200AE PRE-EX to HDI 8 CH UPG

M3200AG LX-5.5 to HDI 8CH UPG FIX

M3200AH LX-5.5 to HDI 8CH UPG T-R

M3200AL HDI 8CH FIXED COLLECTOR

M3200AM HDI 8CH T-R COLLECTOR

M3200AN HDI 8CH MOBILE COLLECTOR

FR3DFSE 3D FSE
acgdplus ACGD Plus
asset Asset
asset91 Asset Plus
bloodsupp Blood Suppression
bravo Bravo
cine Cine
dwepi Diffusion Weighted epi
e3dtof 3D Time of Flight
epli Echo Planer Imaging
fastcine Fast Cine
fastgrass Fast Gradient Echo
flairepi Flair EPI
fse2 Fast Spin Echo & Flair
fsexl FSE-XL
gtof Time of Flight
idrive iDrive
idrivePro iDrive Pro
lava Lava
merge2d 2D Merge
pcvi Phase Contrast Vascular Imaging
sgd SGD_EchoSpeed
sgdperf SGDPerf
smartprep Smart Prep
special SPECIAL
sprep99 Smart Prep 2000 upgrade
ssfse SSFSE
ssfsemrcp SSFSE MRCP/Body Pak
ssfsexl MRCP3
t1bhold T1 Breath Hold
t2bhold T2 Breath Hold
threeplane Three Plane Localizer
ushorttr Ultra Short TR
blflwmaps Blood Flow and Volume Measurements
de3d 3D Dual Echo
MPhVar Multi-Phase Variable Sequences
channel88-Channel
Table 7. Option Key Catalog Matrix for Model Type “MR” (continued)
Option catalog Options activated Customer protocol
M3335JS Multi-Phase (variable delays)

M3335MT LCD MONITOR

MPhVarMulti-phase Variable Sequences
Table 8. Option Key Catalog Matrix for Model Type “MR” (continued)
Option catalog Options activated Customer protocol
M3335KJ Lava-XV lavaxvLAVA-XV
M3335KK Breast Single Voxel Spectroscopy breastsvqBREASE
M3335KM MR-Echo realcard RealCARD
tmcourse Time Course
delenhmtDelayed Enhancement
M3335KP Swift MRA swiftMRA SWIFT
M3335KR BRAINWAVE2.0 RT brnwavrtBrainwave RT
M3335KS BRAINWAVE2.0 PA - CONSOLE brnwavpaBrainwave PA
M3335KT BRAINWAVE FUSION-CONSOLE brnwvfusnBrainwave Fusion
M3335KW 3D Cosmic cosmic3dCosmic 3D
M3335KY T2 Mapping t2mapT2 Mapping - Cartilage Integrity Package
M3335LT Vibrant Bilateral Breast breast2VIBRANT
M3335MJ BRAINWAVE HW FOR HDX brnwavhwBrainwave Light Hardware
Table 9. Option Key Catalog Matrix for Model Type “MR” (continued)
Option catalog Options activated Customer protocol
M7000AY MNS AND 8KW AMP SIGNA 750

M7000B MNS UPGRADE FOR SIGNA 750

mnsMulti-Nuclear Spect
sageSpectro Analysis GE
probepProbePRESS
probe99Probe 2000 Upgrade
probe3dProbe 3D
spectroSpectroscopy/PROBE
M7000CA MR ECHO realcardRealCARD
tmcourseTime Course
delenhmtDelayed Enhancement
M7000CB TRICKS tricksTricks
M7000CC PROSE proseProbe 3D Prostate
M7000CD CARDIAC FGRE-ET perfusionPerfusion
M7000CE CARDIAC REALTIME rtetReal-Time FGRE-ET
M7000CF CARDIAC 2D MDE delenhmtDelayed Enhancement
M7000CG CARDIAC 3D MDE delenhmt3d3D Delayed Enhancement
M7000CH CARDIAC TAGGING taggingCardiac Tagging
M7000CJ COSMIC FOR MR750 cosmic3dCosmic 3D
M7000CK QUICKSTEP FOR MR750 quickstepQuickSTEP
M7000CL 3D CARDIAC NAVIGATOR navigatorNavigator
M7000CN PROPELLER 2.0 propdwiPropeller
propt2Propeller
propnpwPropeller Enh
propbodyBody Propeller
M7000CP IDEAL idealIDEAL
lavadeLAVA-DE
vibrantdeVIBRANT-DE
M7000CR CUBE cubet2Cube T2
FLAIR3D3D FLAIR
M7000CS 3D MERGE merge3d3D MERGE
M7000CT DIFFUSION TENSOR tensorDiffusion Tensor
M7000CW FIBERTRAK tractoTractography (FiberTrak)
M7000CY 2D FATSAT FIESTA MR450 fiesta2dfs2D FatSat FIESTA
M7000CZ 3D FATSAT FIESTA fiesta3dfs3D FatSat Fiesta
M7000EB FUNCTOOL FUSION MR750 fctlfusnFunctool Fusion
M7000EC BRAINSTAT blflwmapsBlood Flow and Volume Measurements
M7000EG VIBRANT breast2VIBRANT
M7000EH BREASE breastsvqBREASE
M7000EJ CARTIGRAM t2mapT2 Mapping - Cartilage Integrity Package
M7000EZ FLOW ANALYSIS flowanalFlow Analysis
M7000FA CONNECTPRO hisrisModality WorkList
M7000FB PERFORMED PROCEDURE STEP ppsPPS
Table 10. Option Key Catalog Matrix for Model Type “MR” (continued)
Option catalog Options activated Customer protocol
M7000MT MR TOUCH touch2dMRTOUCH
M7000PF MAVRIC SL (after DV23.1 software)mavricMAVRIC SL
M7001SAsilentmr1.5T Silent GEM Pkg FP
M7001SCsilentmr3.0T Silent GEM Pkg
M7001SNsilentmra3.0T Silent GEM MRA